Conductors:
Plain annealed circular stranded copper conductors according to BS 6360.Insulation:
Extruded PVC compound type TI 1
Pairs:
Black and white conductors shall be uniformly twisted together to form a pair and numeral
numbering shall be printed along the white core for pair identification.
Pair screen (optional):
When individual pair screen required, aluminium / polyester tape with metallic side
downward in contact with an annealed plain capper drain wire of diameter 0.8mm.
Laying up:
The required number of pair shall be twisted together to form a compact circular core.
Where necessary fillers may be applied.
Overall screen (optional):
When required, aluminium / polyester tape with metallic side downward in
contact with an annealed plain copper drain wire of diameter 0.8mm.
Bedding: (applicable to Type 2 cable only)
Extruded PVC compound type TM 1
Armoured : (applicable to Type 2 cable only)
The armour shall consists of a single layer of galvanised steel wires.
Sheath:
Extruded black or grey PVC compound type TM 1 |